Enviro Tuff 201FR – Single Sided Sisalation
High-Performance Thermal and Acoustic Insulation Solution
Protect your building with Enviro Tuff 201FR – Single Sided Sisalation, a superior insulation product designed for exceptional thermal and acoustic performance. Ideal for a variety of applications, this single-sided reflective foil insulation offers reliable protection against heat, noise, and moisture, enhancing the comfort and energy efficiency of your space.
Key Features:
- Excellent Thermal Insulation: The reflective foil surface effectively reduces radiant heat transfer, keeping interiors cooler in summer and warmer in winter, and contributing to significant energy savings.
- Fire Retardant: Rated as 201FR, this Sisalation product meets stringent fire safety standards, providing added protection and peace of mind.
- Moisture Barrier: Acts as an effective barrier against moisture, preventing condensation and protecting the building structure from potential water damage.
- Acoustic Insulation: Helps in reducing noise transmission, creating a quieter and more comfortable indoor environment.
- Durable Construction: Made from high-quality materials, Enviro Tuff 201FR is built to withstand the rigors of construction and provides long-lasting performance.
- Lightweight and Easy to Install: Its lightweight nature and flexible design make it easy to handle and install, saving time and labor costs during construction.
- Environmentally Friendly: Manufactured using eco-friendly processes and materials, this insulation product contributes to sustainable building practices.
Benefits:
- Energy Efficiency: Enhances the energy efficiency of buildings by improving thermal performance, leading to reduced heating and cooling costs.
- Enhanced Comfort: Maintains a consistent indoor temperature and reduces noise levels, enhancing occupant comfort.
- Versatile Application: Suitable for use in residential, commercial, and industrial buildings, providing a versatile insulation solution for various projects.
- Cost-Effective: Offers excellent value for money by combining thermal, acoustic, and moisture protection in a single product.
- Improved Building Lifespan: Protects against moisture and fire, contributing to the longevity and safety of the building structure.
Applications:
- Residential roofing and walls
- Commercial and industrial buildings
- Warehouses and storage facilities
- Agricultural structures
- Retrofit and new construction projects
Installation Guidelines:
- Preparation: Ensure the surface is clean and dry before installation.
- Measuring and Cutting: Measure the area to be insulated and cut the Enviro Tuff 201FR to the required size.
- Positioning: Position the insulation with the reflective side facing the air space or the direction of the heat source.
- Securing: Secure the insulation using appropriate fasteners or adhesives, following manufacturer guidelines.
- Sealing: Seal all joints and edges with suitable tape to ensure a continuous barrier against heat and moisture.
Order Your Enviro Tuff 201FR – Single Sided Sisalation Today
Enhance the thermal and acoustic performance of your building with Enviro Tuff 201FR – Single Sided Sisalation. Visit our website to learn more and place your order. Experience the perfect blend of fire safety, energy efficiency, and durability with this high-quality insulation solution.
Envirotuff 201FR
Residential Applications
Single sided 3 layer (Woven PE / PE tie layer / aluminium)
Non-tear structure
No delamination
Roll size: 1.25m x 36m
m2 / roll = 45m2
coverage / roll = +- 40.5m2
kg / roll : 3.95kg
No. of rolls per pallet = 144 rolls
R Value Range:
R Value = 1.34 (40mm top/60mm bottom airgap, 50’C top temp, 10’ bottom temp)
R Value = 1.49 (40mm top/60mm bottom airgap, 35’C top temp, 20’ bottom temp)
Fire Rating:
B/B3 – Tested in accordance to SANS10400A (10400T) (SANS 428 part 5/10)
Residential Installation Method
- Envirotuff radiant barrier must be unrolled horizontally across the rafters with the printed aluminium side facing up.
- Envirotuff must be overlapped by 150mm at all joins. 150mm overlap markings are printed onto the rolls for ease of use.
- Envirotuff radiant barrier must be fixed between the rafters and the battens/purlins.
- To ensure maximum performance, an air-gap is required between the Envirotuff radiant barrier and the roof tile/sheeting.
- It is suggested that Envirotuff be pulled hand-taut across the rafters. Do not excessively stretch the material.
- Envirotuff should not be left exposed to sunlight or wind for long periods of time.
Industrial Installation Method
- Straining wire to be installed above the purlins and evenly tensioned. The initial straining wire is to be spaced 75mm away from the gable end, with subsequent spacings at 275mm or 367mm spacings.
- Envirotuff radiant barrier must be unrolled vertically across the rafters with the printed aluminium side facing the airgap.
- Envirotuff must be overlapped by 150mm at all joins. 150mm overlap markings are printed onto the rolls for ease of use.
- It is suggested that Envirotuff be pulled hand-taut across the rafters. Do not excessively stretch the material.
- Envirotuff should not be left exposed to sunlight or wind for long periods of time.